Basic Info
Model NO. | SMSH-8KW |
PV Array Combiner | IP65 |
Battery | 12V/200ah X 24PCS |
OEM/ODM | Accept |
Special Design | Accept |
Solar Cell | Poly Crystalline 156 |
PV Cable | 4mm2 |
System Mounting | Flat Roof |
Mounting Structure | Hot DIP Galvanized Steel |
10 Kw Solar System | 3kw Solar Power System |
Certificate | TUV IEC Ce RoHS |
Type | off-Grid System AC |
Solar Power Generator Life Span | More Than 25years |
Inverter | Pure Sine Wave Output |
Transport Package | Carton or Wood Boxes |
Trademark | SUNMASTER |
Origin | Zhejiang |
HS Code | 8502390000 |
Production Capacity | 50, 000 PCS/Year |
Product Description
Item | Certification | Description | Q'ty | Warranty |
Solar panel | TUV / IEC / EC | Mono or Poly | 2 pcs | 20 years |
Inverter | CGC / CQC / VDE | One (MPPT) tracking/ 50/60Hz; 230Vac 1500W/ SM-SH1500W | 1 set | 5 years |
|
Distribution box (Optional) | CE | Lighting Protection. Air switch,Fusegar, knifeswitch, | 1 set | 5 years |
|
Mounting system | CE | Slant roof bracket/ Cement Ground bracket/ Soil ground bracket | 1set | 10 years |
PV cable | TUV/ UL | DC port PV1-F 1*4mm² | 20m | 10 years |
AC port YJV-3*6mm² | 10m | 10 years |
Type | MONO | POLY |
Power class | 280W | 335W | 270W | 320W |
Open Circuit Voltage (Voc) | 43 | 44 | 43 | 43.8 |
Short Circuit Voltage (Isc) | 8.35 | 9.92 | 8.23 | 9.42 |
Max power Voltage (Vmp) | 36 | 36 | 36 | 36.5 |
Max Power Current (Imp) | 7.78 | 9.3 | 7.35 | 8.76 |
Efficiency | ≥17.1% | ≥17.2% | ≥16.5% | ≥16.4% |
Dimension (mm) | 1650x991x35 | 1960x991x35 | 1650x991x35 | 1960x991x35 |
Weight (kg) | 18±5% | 22.5±5% | 18±5% | 22.5±5% |
Ambient temperature range | -25~+60ºC(>45ºC deloading) |
Relative humidity | 0~95% |
Max operating altitude | 4000m (>3000m derating) |
Protection degree | IP65 |
Topology | Transformerless |
Night power consumption (W) | <1 |
Cooiong method | Natural convection |
Noise emision (dB) | <25 |
Display | LCD |
Warranty (Year) | 5/10/15/20/25 (Optional) Years |
Rated Charge current(A) | 40A |
Rated DC voltage(V) | 24/48 automatic identification |
Solar input Max voltage(V) | 42/84 |
Battery | Over charge protective voltage(V) | 28.6/57.2 |
Battery | Over charge recover voltage(V) | 27.4/54.8 |
Battery | Constant charge voltage(V) | 27/54 |
Battery | Over discharge alarm voltage(V) | 20/40 |
Environment Humidity and temperature | 0-90% No condense,55ºC |
Protective Functions | Protection against anti-charge at night,battery over charge, over discharge protection,Joint-reversed of solar modules |
Nominal Voltage | 12V |
Nominal Capacity | 100Ah(10hr,1.80V/cell,25ºC) |
Approximate Weight | 27.5 kg |
Internal Resistance | 5.5 mΩ(Lead terminal) |
Terminal | Lead wire(4.0mm²×1.8m) |
Maximum Charge Current | 25 A |
Ambient Temperature | -35~55 ºC |
Dimension | Length | 329mm(±2 mm) |
Width | 172mm(±2 mm) |
Container Height | 214mm(±2 mm) |
Total Height | 236mm(±2 mm) |
Case | ABS |
Components | Parameter | Function |
Circuit breaker (Air switch) | 40A | When the current of the protected,circuit exceeds the specified value,the circuit breaker will automatically break off to protect the whole circuit. |
|
|
Fusegear | 40A | When the current of the protected circuit exceeds the specified value,fusegear will break off automatically |
|
Surge protective device (SPD) | UC:420V lmax:20KA In: 10KAUp≤1.8KV | Photovoltaic lightning protection device |
One phase self dual over voltage protection device | Working range 220V,50Hz, over voltage protection Uvo=270V±5V Under voltage protection Uoe= 170±5V | When the circuit voltage is highet or lower, it will shut down automatically.when the voltage reaches standard level, it will recover automatically. |
|
Knife switch | / | automatic/ by hand |
Conductor | Tinned Fine Re Copper Strand, according to VDE0295/IEC60228. Class 5 |
Insulation | Polyolefin Copolymer electron-beam coss-linked |
Sheath Jacket | Polyolefin Copolymer electron-beam coss-linked |
Nominal Voltage | Uo/U=600V/1000VAC, 1000V/1800VDC |
Test Voltage | 6500V, 50Hz, 5Min |
Temperature Rating | -40°C-125°C ,More than 25 Years (TUV) |
Fire Performance | IEC 60332-1 |
Smoke Emission | IEC61034, EN 50286-2 |
Low Fire Load | DIN 51 900 |
Certification | TUV 2PFG 1169/08 2007 PV1--F |
The wind capacity of such mounting system can reach (40m/s, 32.5kg/ square meters, level 13), snow load capacity can reach 70kg/ square eters
The whole system has strong safety performance.
Can be customized based on customer's cactual situation
The mounting system can be desingned with best solution based on slope roof, flat ground and soil ground